OUR DATA CENTRES

Our hosting services are delivered from highly resilient and secure data centres.

ABOUT OUR DATA CENTRES

Our cloud hosting services are delivered from highly resilient and secure data centres located in London, Manchester, Singapore and coming soon, North America and Germany.

We own everything else outright from the racks to switches, servers, and storage. Our global network is resilient, scalable, compliant and secure. 

Our gridz platform is an enterprise cloud platform that we can lift and put anywhere in the world at lightning fast pace.

When we manage your private cloud we maintain and secure everything. Our ISO accreditations, compliance experience, and expertise coupled with an enterprise level service delivery practice ensure that your applications are safe, fast, secure, private and compliant.  

TALK TO US

TELEHOUSE NORTH

Telehouse North
Telehouse

Opened in 1990, it was the first purpose-built colocation data centre in Europe. Telehouse North has been the primary home of the London Internet Exchange since 1994 and continues to be one of the most heavily connected data centre in the world.

It is ideal for telecom providers, financial trading exchanges, media and gaming companies that require speed, reliability and reach. Telehouse North is one of four Telehouse data centres within London and is placed adjacent to the existing sites in the heart of London’s Docklands.

Power Supply

POWER

  • Average power per rack – 1 to 3kW
  • 2. 3 x multiple diverse power route incoming feeds
  • 4 x Generators with N +1 redundancy
  • 15 mins of UPS battery autonomy with N+1 or N+N redundancy depending on location.
Connectivity

CONNECTIVITY

  • Carrier neutral facility offering customers freedom of choice
  • Direct access to over 100 carriers
  • With the Interlink Service clients can connect to any carrier from any Telehouse data centre
  • Hosts the London Internet Exchange allowing low-latency connectivity
Certification

CERTIFICATION

  • ISO 9001:2008 Quality Management Standard
  • ISO 14001:2004 Environmental Management System Standard
  • ISO/IEC 27001:2005 Information Security Management
  • PCI – DSS (Payment Card Industry – Data Security Standard) Attestation
  • BS 25999-2:2007 Business Continuity Management
  • The Carbon Trust Standard
Fire Detection and Suppression

FIRE DETECTION AND SUPPRESSION

  • Very early smoke detection alarms (VESDA) installed throughout the facility
  • Fully addressable two stage fire detection system that monitors both under-floor and the room itself
  • Detectors with 50% mix of optical and ionisation are split across two separate zonal-loops, to meet BS5839, 6266, 5445 and 5588
  • Dry sprinkler fire detection system to meet BS 5306, 3115 and with LFEPA approval
  • Ceilings, walls, floors and doors comply with RF90 (fire resistance 90 mins) in DC areas, telecom and plant areas
Air Conditioning

AIR CONDITIONING & COOLING

  • Air conditioning at N 1 redundancy
  • The heat rejection system is 30% glycol and condensed water which utilises dry heat rejection condensers on the rooftop
  • Full function, closed control air conditioning system, with cooling, humidity and de-humidification control
  • Room design temperature: 22 degrees C, plus or minus 1 degree C. Room humidity: 50% rH. Plus 10% or minus 10% rH
  • External Temperature Design: 35 degree C Dry Bulb
  • There is a redundant “A” and “B” pipe work route to the roof top condenser system and N 1 pump system in the North Building to circulate the glycol condensed water to the data centre in-room air package equipment
Security

SECURITY

  • Perimeter protected by alarmed fences and PIR detection
  • Gated entrances manned combined with a security management system to ensure no unauthorised access to the site
  • Movement activated CCTV coverage for the Perimeter, Entrances and Loading Docks, Common areas reception and corridors and of course our state of the art suites
  • Single point of entry to our main facilities controlled by time limited access cards combined with card Independent client card identification access system and integrated digital video camera surveillance
  • Proximity card access is provided from the main data centre building and is issued to provide access only to authorised facilities management suites
  • Strict security processes are in place to ensure delivery and loading of goods are secure
  • Doors fitted with alarms that immediately report back to a manned security suite when unauthorised access is attempted or doors are forced or held open
  • A highly trained Security presence 24/7 to ensure that you and your nominated staff gain authorised access to the facility whenever you require, day or night

TELEHOUSE EAST

Telehouse East
Telehouse

Telehouse East is one of four Telehouse data centres within London and is placed adjacent to the existing sites in the heart of London’s Docklands.

It is ideal for organisations that require highly connected, low-latency data centre space and offers a superlative environment for a primary or secondary site for mission-critical systems.

Due to the vast number of carriers and as a home to the London Internet Exchange, Telehouse East is ideally designed for financial trading exchanges, media and content providers that require speed, reliability and reach.

Power Supply

POWER

  • Average power per rack – 1 to 2kW
  • 2 x multiple diverse power route incoming feeds
  • 5 x Generators with N +1 redundancy
  • 15 mins of UPS battery autonomy with N+1 redundancy
Connectivity

CONNECTIVITY

  • Carrier neutral facility offering customers freedom of choice
  • Direct access to over 100 carriers
  • With the Interlink Service clients can connect to any carrier from any Telehouse data centre
  • Hosts the London Internet Exchange allowing low-latency connectivity
  • In 2012 London Internet Exchange doubled its capacity to 9.6TB at the Telehouse site
Certification

CERTIFICATION

  • ISO 9001:2008 Quality Management Standard
  • ISO 14001:2004 Environmental Management System Standard
  • ISO/IEC 27001:2005 Information Security Management
  • PCI – DSS (Payment Card Industry – Data Security Standard) Attestation
  • BS 25999-2:2007 Business Continuity Management
  • The Carbon Trust Standard
Fire Detection and Suppression

FIRE DETECTION AND SUPPRESSION

  • Very early smoke detection alarms (VESDA) installed throughout the facility
  • Fully addressable two stage fire detection system that monitors both under-floor and the room itself
  • Detectors with 50% mix of optical and ionisation are split across two separate zonal-loops, to meet BS5839, 6266, 5445 and 5588
  • Dry sprinkler fire detection system to meet BS 5306, 3115 and with LFEPA approval
  • Ceilings, walls, floors and doors comply with RF90 (fire resistance 90 mins) in DC areas, telecom and plant areas
Air Conditioning

AIR CONDITIONING & COOLING

  • Air conditioning is provided at N 1 redundancy
  • The heat rejection system is 30% glycol and condensed water which utilises dry heat rejection condensers on the rooftop
  • Full function, closed control air conditioning system, with cooling, humidity and de-humidification control
  • Room design temperature: 22 degrees C, plus or minus 1 degree C. Room humidity: 50% rH. Plus 10% or minus 10% rH
  • External Temperature Design: 35 degree C Dry Bulb
  • The East Building works on “A” or “B” pipe work to room with N N redundant units and N N pumps
Security

SECURITY

  • Perimeter protected by alarmed fences and PIR detection
  • Gated entrances manned combined with a security management system to ensure no unauthorised access to the site
  • Movement activated CCTV coverage for the Perimeter, Entrances and Loading Docks, Common areas reception and corridors and of course our state of the art suites
  • Single point of entry to our main facilities controlled by time limited access cards combined with card Independent client card identification access system and integrated digital video camera surveillance
  • Proximity card access is provided from the main data centre building and is issued to provide access only to authorised facilities management suites
  • Strict security processes are in place to ensure delivery and loading of goods are secure
  • Doors fitted with alarms that immediately report back to a manned security suite when unauthorised access is attempted or doors are forced or held open
  • A highly trained Security presence 24/7 to ensure that you and your nominated staff gain authorised access to the facility whenever you require, day or night

TELEHOUSE SINGAPORE

Telehouse Singapore
Telehouse

Telehouse Singapore is a state-of-the-art Tier 3 plus data centre situated in a prime industrial location in the east of Singapore Island.

With the vast number of multinationals expanding their presence in Asia through Singapore, the country has quickly become a hot spot for data centre and cloud computing development.

Designed as a technically leading facility with accessibility, infrastructure and risk reduction in mind, our Telehouse data centre is located 20 minutes from the city centre and Changi airport in one of the safest regions in Asia. 

Power Supply

POWER

  • Standard power per rack at 2.5kVA with a maximum power supply of 5kVA
  • Two independent power supply from different power stations
  • 2N UPS system with capacity at 15 minutes fully charged
  • +1 oil-driven private generators able to run for 24 hours continuously
  • Average power supply at 860W/m² with a maximum at 1640W/m²
Connectivity

CONNECTIVITY

  • ISO 9001:2008 Quality Management Standard
  • ISO 14001:2004 Environmental Management System Standard
  • ISO/IEC 27001:2005 Information Security Management
  • PCI – DSS (Payment Card Industry – Data Security Standard) Attestation
  • BS 25999-2:2007 Business Continuity Management
  • The Carbon Trust Standard
Certification

CERTIFICATION

  • ISO 9001:2008 Quality Management Standard
  • ISO 14001:2004 Environmental Management System Standard
  • ISO/IEC 27001:2005 Information Security Management
  • PCI – DSS (Payment Card Industry – Data Security Standard) Attestation
  • BS 25999-2:2007 Business Continuity Management
  • The Carbon Trust Standard
Fire Detection and Suppression

FIRE DETECTION AND SUPPRESSION

  • Fire prevention system uses inert gas
  • Pre-action sprinkler installed
  • Early smoke detection system in place with automatic fire extinguishing facility operating without damaging client equipment
Air Conditioning

AIR CONDITIONING & COOLING

  • Latest high volume air-conditioning system
  • N+2 redundancy climate control configuration
  • Thorough humidity and temperature management
  • Highly sensitive monitoring system enables immediate detection and response to facility environmental changes
Security

SECURITY

  • 24-hour on-site personnel monitoring security of premises
  • 24/7 CCTV surveillance cameras are installed around data centre
  • Biometric sensor verifies identity by using vein patterns, located at entrance to colocation space
  • Single-point entry used to prevent potential intruders tail gating into data centre
Additional Specification

ADDITIONAL INFORMATION

  • 600mm height of raised floor
  • 100% anti-static flooring throughout
  • Floor load at 824kg/m²
  • NOC operators working 24/7 within data centre to monitor operation status of equipment and to maintain stability
  • Bi-lingual helpdesk and support for multinational companies
  • Free of charge meeting space, internet connection via wireless LAN, tools rental and storage service for engineers

EQUINIX MA2

Equinix MA2
Equinix

This Equinix International Business Exchange™ (IBX) offers access to a rich digital ecosystem including IX Manchester and the London Internet exchange (LINX), as well as customer peering via the Amsterdam Internet exchange (AMS-IX). 

Power Supply

POWER

  • Number of independent supplies into building: 2
  • From how many substations: 2
  • Total incoming feed capacity (MVA): 3
  • Diverse power route: 4
  • Generator fuel at full load (hours): 168
  • UPS type: Static
  • UPS autonomy (minutes): 15
  • UPS capacity (kW): 1408
  • UPS redundancy: N+1
  • Generator redundancy: N
  • Generator capacity (MVA): 7.5
Connectivity

CONNECTIVITY

  • Number of diverse entry points into building: 4
  • Number of meet me rooms: 3
Certification

CERTIFICATION

  • ISO 27001 Information Security Management
  • ISO 9001 Quality Management
  • ISO 14001 Environmental Management
  • ISO 50001 Energy Management
  • ISO 22301 Business Continuity Management
  • OHSAS 18001 Occupational Health and Safety Management
  • PCI DSS Payment card industry data security standards
Fire Detection and Suppression

FIRE DETECTION AND SUPPRESSION

  • High sensitivity smoke detection system:   Yes
  • Type of fire suppression system:   Automatic/Manual (FM200 & Argonite)
Air Conditioning

AIR CONDITIONING & COOLING

  • Type of cooling system: DX CRAC units
  • Maximum cooling capacity (MW): 1.7
  • Cooling redundancy: N+1
  • CCUs or in-row cooling: CCU
Security

SECURITY

  • Type of security system:   Proximity access card
  • Staffed 24/7/365: Yes
Additional Specification

ADDITIONAL INFORMATION

  • Gross size of data centre (m²): 2684
  • Net customer space (m²): 2142
  • Building type: Converted telecoms building
  • Building tenure: Leasehold
  • Number of data floors: 3
  • Number of IT zones: 4
  • Maximum floor load capacity (kg/m²): 1500
  • Maximum raised access floor height (mm): 600
  • Raised floor to false ceiling height (metres

EQUINIX LD5

Equinix LD5
Equinix

LD5 is one of many state-of-the-art IBX centres in key metropolitan areas throughout EMEA that offer a full range of premium co-location, interconnection, and support services to a wide range of secure digital ecosystems built by networks, enterprise, content, cloud and IT services companies and financial institutions. 

Power Supply

POWER

  • UPS redundancy: N+1
Connectivity

CONNECTIVITY

  • ISO 27001 Information Security Management
  • ISO 9001 Quality Management
  • ISO 50001 Energy Management
  • OHSAS 18001 Occupational Health and Safety Management
  • FACT Intellectual Property Security Compliance
  • PCI DSS Payment card industry data security standards
  • SSAE16/ISAE3402 SOC-1 Type II
Certification

CERTIFICATION

  • Cooling redundancy: N+1
Additional Specification

ADDITIONAL INFORMATION

  • Break Room
  • Loaner Tools
  • Showers
  • Crash Carts
  • Work kiosks
  • Wifi
  • Conference Room

Isn't it time you reviewed your technology partners?

We have multiple service options here at zsah. No matter what your budget, we can find a technology solution that will fit your situation.

Take the quiz or call our office now at 020 7060 6032 to discuss further.

np_business-partner_934833_EFD01B
Zsah Technology Partners
ISO9001 ISO27001
HM Government G-Cloud
Digital Outcomes & Specialists
Crown Commercial Service

About zsah

Since 2002, we have been providing managed technology services from our headquarters in Central London.

We consist of some of the most accomplished technical and service driven people coupled with a management team that has huge business acumen. 

We ensure that we stay ahead of the competition with industry-leading accreditations and partnerships with established names in the technology industry.

TALK TO US

Prepare for tomorrow. Call us today.

Drop by our office, call or email us anytime to arrange a meeting.

CHOOSE A SERVICE